Description
Technical specifications
| Modifications | revilasil Revilasil Mini Revilas Maxie. |
| Materials | polypropylene |
| Dimensions, mm | Revilasil – 50 x 50 x 17 Revilasil Mini – 28 x 70 x 17 Revilasil Maxi – 85 x 83 x 41 |
| Colour | Black, for Revilasil Maxi other colors are possible |
| Temperature of use, °C | -5 to +75 |
| Resource of application, discovery / closing |
Revilasil – 2,500 Revilasil Mini – 1,000 Revilasil Maxi – 2,500 |
| Installation of the device | It is attached to the door with screws (bolts) |
| Seal installation | manually |
| Removal of the seal | manually |
| Minimum shipment (multiple batch of sales), pc. |
1 |
| Installation of sealed devices “Revilasil” on the locking part of the door is made with the help of four screws (bolts) in such a way as to exclude the possibility of separation of the device from the door without visible signs. With a significantly protruding part of the lock, special rings that are part of the device are used for the installation of Revilasil.
Sealing of the device is made manually in the following order: the key closes the door lock, the device lid is closed with a light effort, then in a special sealing chamber formed by combined holes of the closed lid and the fixed part of the device, before clicking, the Envopolisil seal is inserted so that its number is visible. The number of the seal is recorded in the registration log. The device is opened in the following order: the seal number is checked with the one recorded in the registration log, the device and the seal are checked for the absence of opening traces, then the Envopolisil seal is broken by a light force applied to its rectangular flag in the direction from the device. Then the lid of the device is opened with a light hand effort at an angle not exceeding 90 degrees, the key opens the door lock. After that, the cover of the device is closed (during the working day is in a closed, unsealed state). The fragment of the “anchor” of the seal is removed from the chamber of the sealed device, inspected for unauthorized effects and, in their absence, disposed of together with the seal. When using the sealing device, it is strictly prohibited: opening the cover at an angle of more than 90 degrees; Leave the lid open during the working day; use the cover of the sealing device as a lever for breaking the seal “Envopolisil”; apply to the cover forces perpendicular to the opening plane. With proper operation of the device, at least 2,500 openings and closures for the Revilasil device are guaranteed. The visual sign of an attempt to open or reuse the seal “Envopolisil” is: the presence of signs of thermal effects or traces of chemical reagents (adhesives) on the surface of the seal at the fault site; the inreadability of the logo and the number of the seal; Free removal of the seal from the opening of the sealing chamber. |